WENZHOU QIUPU ELECTRIC POWER CO., LTD.

WenZhou QiuPu Electric Power Co., Ltd. BECOME CHINA'S FIRST-CLASS PRODUCTION AND SALES OF HIGH-TECH ENTERPRISES .

Manufacturer from China
Verified Supplier
8 Years
Home / Products / Zinc Oxide Lightning Arrester /

Outdoor Zinc Oxide Lightning Arrester , 40.5kV HV Metal Oxide Surge Arrester

Contact Now
WENZHOU QIUPU ELECTRIC POWER CO., LTD.
Visit Website
Province/State:zhejiang
Country/Region:china
Contact Person:MrCheng
Contact Now

Outdoor Zinc Oxide Lightning Arrester , 40.5kV HV Metal Oxide Surge Arrester

Ask Latest Price
Brand Name :QIUPU
Model Number :HY5WZ-51/134J
Certification :IEC
Place of Origin :WENZHOU
MOQ :51 PCS
Payment Terms :T/T, Western Union
Supply Ability :500000PCS/MONTH
Delivery Time :7 Days
Packaging Details :CARTONS
Rate Voltage :40.5kV
Frequency Voltage :100kV
Rate Current :100A-200A
Shock voltage :100-170 BIL
2 Ms Current :600A
Short Current :100kA
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

HY5WZ-51/134J Zinc Oxide Lightning Arrester with Electrical switchgear euipment

The lightning arrester is an electrical appliance used to protect the electrical equipment from high transient overvoltage and to limit the duration of continuous flow. The term includes any external clearance necessary for the normal functioning of the appliance at run time, whether or not it is a component of the whole. The lightning rod is to install a metal rod at the top of a tall building, to connect the metal rod with a metal plate buried in the ground, and to use the tip discharge of the metal rod and the conductivity of the metal, so that the electricity carried by the cloud is directly neutralized by electricity from large areas, thus protecting the building from lightning strikes.

The measurement of insulation resistance, for the FS-type lightning arrester, is mainly to check the seal situation, if the seal is not strict will inevitably cause internal dampness, so that the insulation resistance obviously decreased. In accordance with the pre-test procedure, the measurement shall be carried out by testing the 2500V megabyte meter, and the insulation resistance shall be not less than 2500M.

Rated Voltage Work Voltage AC Current
35kV 43.2kV 76A

The difference between lightning arrester and lightning rod is that lightning arrester is a part, a kind of equipment, and has its own function. The lightning rod is an integral part of the system, which is made of round steel, and the connecting wire and grounding wire together form a system to perform lightning avoidance function. The concepts are as follows:

Inquiry Cart 0