WENZHOU QIUPU ELECTRIC POWER CO., LTD.

WenZhou QiuPu Electric Power Co., Ltd. BECOME CHINA'S FIRST-CLASS PRODUCTION AND SALES OF HIGH-TECH ENTERPRISES .

Manufacturer from China
Verified Supplier
8 Years
Home / Products / Electrical Switchgear Components /

Power Transmission Metal Clad Switchgear 12KV Removable

Contact Now
WENZHOU QIUPU ELECTRIC POWER CO., LTD.
Visit Website
Province/State:zhejiang
Country/Region:china
Contact Person:MrCheng
Contact Now

Power Transmission Metal Clad Switchgear 12KV Removable

Ask Latest Price
Video Channel
Brand Name :Qiupu
Model Number :KYN28-24
Certification :GB17467
Place of Origin :wenzhou
MOQ :Negotiable
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :5000
Delivery Time :7 days
Color :white/stainless steel/customized
Application :Electric Power Transmission
Rated Voltage :12KV
Rated frequency :50-60HZ
Protection Level :IP30/IP32/IP40/IP65/IP66
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

KYN28-24 Armored removable AC metal-enclosed switchgear

Product description

KYN28-24 (Z) (GZS1) armored removable AC metal-enclosed switchgear (hereinafter referred to as "switching device"), suitable for three-phase AC 50Hz power system, used to receive and distribute electrical energy and control and protect the circuit And monitoring.
This product complies with the standards: GB3906-2006 "3.6-40.5kV AC metal-enclosed switchgear and control equipment", GB/T11022 "High-voltage switchgear and control equipment standard common technical requirements", IEC62271:200 "rated voltage above lkV and below 52 AC Metal-enclosed Switchgear and Control Equipment", DL/T404 "Indoor AC High Voltage Switchgear Ordering Technical Conditions".

Model and its meaning

Power Transmission Metal Clad Switchgear 12KV Removable

① Armored

② Removable

③ Indoor

④ Design serial number

⑤ Rated voltage (kV)
⑥ Vacuum circuit breaker

Conditions of Use

• Ambient air temperature: the highest temperature is 40°C, the lowest temperature is -15°C;
• Relative humidity: the daily average value is not more than 95%, the daily average water vapor pressure is not more than 2.2Kpa, the monthly average value is not more than 90%, and the monthly average water vapor pressure is not more than 1.8Kpa;
• Altitude: 1000m and below;
• Earthquake intensity: no more than 8 degrees;
• The surrounding air should not be significantly polluted by corrosive or combustible gas, water vapor, etc.;
• There is no frequent severe vibration place;
• When used under normal environmental conditions exceeding GB3906B, it shall be negotiated by the user and the manufacturer.

Technical Parameters

Name Unit parameter
Rated voltage kV 24
Rated frequency Hz 50
Circuit breaker rated current A 630, 1250, 1600, 2000, 2500, 3150
Switch cabinet rated current A 630, 1250, 1600, 2000, 2500, 3150
Rated dynamic stability current (4s) kA 20,25,31.5
Rated stable current (peak value) kA 50, 63, 80
Rated short-circuit breaking current kA 20,25,31.5
Rated short-circuit making current (peak value) kA 50, 63, 80
Rated insulation level imin工频 极间,极对地间 断口间 1 min power frequency withstand voltage Between poles, relative to ground kV 65
Fracture kV 79
Lightning impulse withstand voltage (peak value) Between poles, relative to ground kV 125
Fracture kV 145
Protection level External IP4X, isolation, IP2X when the circuit breaker door is opened

Installation dimension drawing

Power Transmission Metal Clad Switchgear 12KV Removable

A. Busbar room
B. Circuit breaker handcart room
C. Cable room
D. Relay instrument room
1. Shell
2. Branch bus
3. Bus bushing
4. Main bus
5. Static contact
6. Static contact box
7. Current transformer
8. Grounding switch
9. Cable

10. Lightning arrester
11. Grounding main bus
12. Loading and unloading partitions
13. Partition (trap)
14. Secondary plug
15. Circuit breaker handcart
16. Heating device
17. Withdrawable horizontal partition
18. Grounding switch operating mechanism
19. Bottom plate
20. Pressure relief device
21. Control wire duct

Need to know when ordering

The user needs to provide the following information if ordering:
• The main circuit diagram number, purpose and single-line system diagram, rated voltage, rated current, rated short-circuit breaking current, distribution room layout and switchgear arrangement layout, etc. • Requirements for control, measurement and protection functions of switchgear, as well as requirements for other locking and automatic devices.
• The model, specification and quantity of the main electrical components in the switchgear.
• If the busbar bridge connection is required between switchgear or the incoming cabinet, the rated current carrying capacity of the busbar bridge, the span of the busbar bridge, the height from the ground and other specific requirements data are provided.
• When the switchgear is used under special environmental conditions, it should be specified when ordering.
• Other special requirements.

high voltage switchgear components,lightning impulse withstand voltage